Вопрос:
Здравствуйте. Имеется система хранения EonStor A12E-G2121. Сетевые интерфейсы не настроены, получение сетевых настроек по DHCP отключено. Эмуляция терминала на порту RS-232 отключена. Т.е. получить доступ для конфигурации массива невозможно ни по сети, ни через COM-порт. Каким образом восстановить заводские настройки? Спасибо.

Ответ:
Restore Factory Defaults on the A12E-G2121

* Warning *

1. By performing the Restore Factory Defaults Procedure, all

the settings the user made to the controller will be

cleared. All the settings in the controller will be reset

to the factory default values.

2. This procedure will NOT perform any read/write access to

the hard drives or logical drive. However, the logical

drive LUN mapping will be cleared and it is a must to

re-map the host LUN to the logical drive/partition.

* Write Down the Current Settings First *

Please use the chapter - "Record the Settings" in the

Manual to record all the current setting before

performing the Restore Factory Defaults Procedure.

Restore Factory Defaults Procedure:

1. Power off the RAID controller.

2. Pull out the controller from chassis.

3. Next to the memory slot on the controller board is the jumper area.

Please have a look for Jumper Pin J6 (Default Set).

It is in a red square on the picture.

4. Move the Jumper from Jumper Pin J5 (Fan ON/OFF) and plug into

the Jumper Pin J6 (Default Set).

5. Put the controller back to the chassis.

6. Power on the RAID controller.

7. Wait till the system is starting to beep (Ignore the first short initial beep)

8. Power off the RAID controller.

9. Pull out the controller from chassis.

10. Remove the Jumper from Jumper Pin J6 (Default Set) and

put it back into the Jumper Pin J5 (Fan ON/OFF).

11. Put the controller back to the chassis.

12. Power off the RAID controller.

13. After the controller reset completed.

14. Set all the controller settings back according to the

information recorded before perform the procedure.

15. Map the Logical Drive / Partitions to the host ID/LUN again.

http://esupport.infortrend-europe.com/ift/kb/jumpers.jpg